This is all of the information we have on the SRA extractors we had been pairing with our machines. The manual(s) are attached at the bottom of the article. 


NOTE: As of JUL 2021, we are working with BOFA for our extractors. More on that here:

BOFA Fume Extractors

Specifications



MODEL
480XP
500XL
1200XL
FITMENTMini60/Nova24/Odin22Nova35Nova51/Nova63
DIMENSIONS420x420x520mm450x490x880mm730x690x1415mm
PACKAGE52x47x92cm 45kg carton52x60x106cm 78kg crate75x78x156cm 200kg crate


Consumable Life Expectancy (can vary depending on frequency of use, materials being processed, etc...):



 
MODEL
480XP
500XL
1200XL
PRE FILTER1-3 Months1-3 Months1-3 Months
MAIN  FILTER6 Months6 Months6 Months
GAS FILTERNA6 Months6 Months


Please contact sales@thunderlaserusa.com for pricing, availability, details, and consumables.

Maintenance


When the numbers of digital screen>50%, the yellow light will turns on. It shows that the extraction power not strong, the filter cloth and the pre-filter need to be replaced.



  1. Replace the filter cloth(optional items) first. The filter cloth is used to filter large particles of dust.

If the yellow light is still on, go step 2.


  1. Replace the Pre-filter

1. Open the upper front door

2. Use an Allen key to loosen the screw

3. Pull the Pre-filter out


4. Install new Pre-filter

5.Tight the screw clockwise

6. Lock the door

Note:

  1. After you install it the new Pre-filter, please arrange all three layers of filter neatly.

  2. Please confirm whether the screws are tightened


If the yellow light still on after replacing the Pre-filter, then please replace the Main-filter.

The Gas filter mainly removes harmful gases such as TVOC in the air, and the replacement cycle is different according to the degree of environmental pollution. It is generally recommended to replace the main filter at the same time; if the dust-free workshop has a low TVOC concentration, the replacement cycle can be extended.


Recommended replacement time:


Pre-filter: 1-3 months



Main-filter: 6 months



Gas Filter (if applicable) 6 months