8.1 General Maintenance
Caution-Before any maintenance efforts takes place, ensure that the power supply has
been cut off and the system is powered off.
All maintenance efforts must be carried out according to the safety regulations.
In order to ensure the maximum availability and lifespan of the system, we recommend that you regularly
check the ventilation and keep the surrounding area clean.
Lubricating the rotary
It is suggested to add lubricant oil (or Rust Preventative Grease) to the chuck at least every two weeks.
8.2 Clean the Field lens
This system is equipped with high-quality optical components, which, under normal operating conditions,
are free for maintenance within their lifespan. However, it may be necessary to clean output lenses, e.g.
the scanner flat field lens (f-theta objective) needs cleaning if it is covered in dust or fumes.
1. Never touch the optical components with your fingers! Oily or dirty hands may damage the surfaces
of lens.
2. Do not use any tools or hard objects to clean the surfaces. Scratches cannot be repaired.
3. Blow away large pieces of dirt by blowing up a balloon.